EPSON Stylus CX4300/CX4400/CX5500/CX5600/DX4400/DX4450
Revision A
TROUBLESHOOTING
Troubleshooting
49
• Power on
• Anywhere
When turning on the power, the CR
Motor does not operate at all.
CR Motor
1. Check if the CR Motor Connector Cable is connected to
J7 on the Main Board.
1. Connect the CR Motor Connector Cable to J7
on the Main Board.
2. Check if the CR Motor Connector Cable is not damaged.
2. Replace the CR Motor with a new one.
3. Check if the CR Motor operates.
3. Replace the CR Motor with a new one.
When turning on the power, the PF
Motor does not operate at all.
PF Motor
1. Check if the PF Motor Connector Cable is connected to
J8 on the Main Board.
1. Connect the PF Motor Connector Cable to J8
on the Main Board.
2. Check if the coil resistance of the PF Motor is about 4.3
Ω
by using the tester
(refer to Table 3-1)
2. Replace the PF Motor with a new one.
3. Check if the PF Motor Connector Cable is not damaged.
3. Replace the PF Motor with a new one.
4. Check if the PF Motor operates.
4. Replace the PF Motor with a new one.
Table 3-12. Check point for fatal error according to each phenomenon
Occurrence
timing
CR position
Detailed phenomenon
Defective
unit/part name
Check point
Remedy
J7
CR Motor
CR Motor
Connector Cable
PF Motor
Connector Cable
J8
Summary of Contents for CX4400 - Stylus Color Inkjet
Page 5: ...Revision Status Revision Issued Date Description A April 23 2007 First Release ...
Page 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 23: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 32: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 60: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY ...
Page 100: ...C H A P T E R 5 ADJUSTMENT ...
Page 108: ...C H A P T E R 6 MAINTENANCE ...
Page 115: ...C H A P T E R 7 APPENDIX ...
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......