Maintenance 4. Replacing the Cable Unit
E2C Rev.6
93
(9) Loosen the duct joint.
To loosen it, use either a spanner wrench
(width across flats: 51 mm) or a pair of
water pump pliers.
Base connector box
Duct joint
(10) Detach the duct joint from the nut, and then pull out the cables of the duct support
and base plate.
(11) Remove the arm top cover.
For details on the removal method, refer to
Maintenance: 3.1 Arm Top Cover
.
Remember the cable layout so that the cables can be reconnected correctly after
replacement.
(12) Cut off the wire tie binding the duct plate, motor, and cables together.
(13)
Disconnect the pneumatic tubes and
ground terminal on the arm side.
To disconnect the pneumatic tubes, push
the ring on each pneumatic tube fitting and
pull out its tube.
To disconnect the ground terminal,
unscrew the mounting bolt for ground
terminal on the duct plate.
Mounting bolt for ground terminal
M4
×
8
Pneumatic
tube fitting
(14) Remove the duct plate from Arm #2.
Duct plate
3-M5
×
15
(15) Cut off the wire tie binding cables to the
duct plate.
Wire tie
)
NOTE