Maintenance 4. Replacing the Cable Unit
Installation
(1) Pass cables through the base connector box
and a nut.
Secure the duct joint and cable support
with the nut.
Base connector box
Duct joint
(2) Connect the pneumatic tubes, ground wire,
and connectors.
For details, refer to
Maintenance: 4.3
Wiring Schematics/4.4 Block Diagrams
.
(3) Secure a receptacle to the base connector
box.
Receptacle
4-M3
×
8
Ground
terminal
Pneumatic tube fittings
M4
×
8
(4) Fasten the cables to the cable support with
a wire tie.
Attach a ferrite core to the bundle.
Wire tie
Ferrite core
(5) Install the base connector box.
For details on the installation method, refer to
Maintenance: 3.4 Base Connector Box
.
(6) Pass the cable unit through the arm top
cover and duct plate.
Install the duct joint to the duct plate.
Duct joint
Lock nut
(7) Loosely fasten the cables to the duct plate
using a wire tie.
Loosely fastening the cables will allow you
to adjust the length of the cables when
connecting pneumatic tubes, ground wires,
and connectors.
Wire tie
E2C Rev.6