Maintenance 5. Replacing the Motors (Joint #1)
Installation
(1) Mount the motor flange on the Joint #1
motor.
(2) Mount the waveform generator on the Joint
#1 motor.
Be sure to fit the end face of the waveform
generator to the end face of the motor
shaft. Tighten one of the setscrews on the
flat face of the motor shaft until the screw
just touches the surface. Insert a bushing
into the other setscrew hole to prevent
damage to the motor shaft. Then, tighten
both setscrews.
Bushing
M4
×
6
(Round
chamfer side)
Waveform
generator
Motor flange
M4
×
6
(Flat side)
End face of
motor shaft
End face of
waveform generator
Flat
CAUTION
■
See the figures above for the orientation of the waveform generator. Be sure to
install the waveform generator properly. Improper installation of the waveform
generator will result in improper function of the Manipulator.
(3) Insert the oil seal and mount the Joint #1
motor unit on the base.
The motor cable must face toward the base
connector box side.
For the bolt on the maintenance hole side,
loosely fasten it with an accessory tool.
Then, insert a hexagonal wrench from the
maintenance hole and secure the bolt.
If it is difficult to mount the motor, push it
while moving Arm #1 slowly by hand.
Motor flange
3-M4
×
10
(4) Connect the connectors X110 and X11.
(5)
Attach the maintenance plate.
Maintenance
plate
Maintenance hole
2-M3
×
6
double-sems screw
X11
X110
110
E2C Rev.6
Summary of Contents for E2C Series
Page 1: ...SCARA ROBOT E2C series MANIPULATOR MANUAL Rev 6 EM069R1409F ...
Page 2: ...MANIPULATOR MANUAL E2C series Rev 6 ...
Page 8: ...vi E2C Rev 6 ...
Page 14: ......
Page 82: ......
Page 92: ...Maintenance 2 General Maintenance 80 E2C Rev 6 ...
Page 118: ...Maintenance 4 Replacing the Cable Unit 106 E2C Rev 6 ...
Page 194: ...Maintenance 11 Replacing the Signal Relay Board 182 E2C Rev 6 ...