Setup & Operation 3. Environments and Installation
24
E2C Rev.6
3.2 Base Table
A base table for anchoring the Manipulator is not supplied. Please make or obtain the
base table for your Manipulator. The shape and size of the base table differs depending
on the use of the robot system. For your reference, we list some Manipulator table
requirements here.
The base table must not only be able to bear the weight of the Manipulator but also be able
to withstand the dynamic movement of the Manipulator when the Manipulator operates at
maximum acceleration. Ensure that there is enough strength on the base table by
attaching reinforcing materials such as crossbeams.
The torque and reaction force produced by the movement of the Manipulator are as
follows:
Max. Reaction torque on the horizontal plate : 250Nm
Max. Horizontal reaction force
: 900N
Max. Vertical reaction force
: 1000N
♦
The threaded holes for the Manipulator base are M8. Use the mounting bolts
conforming to the strength, ISO898-1 property class: 10.9 or 12.9. For the
dimensions, refer to
Setup & Operation: 3.3 Mounting Dimensions
.
♦
The plate for the Manipulator mounting face should be 20 mm thick or more and made
of steel to reduce vibration. The surface roughness of the steel plate should be 25 µm
or less.
♦
The table must be secured on the floor or wall to prevent it from moving.
♦
The Manipulator must be installed horizontally.
♦
When using a leveler to adjust the height of the base table, use a screw with M16
diameter or more.
♦
If making holes for the cables and passing the cables through the holes on the base
table, see figures below.
50
65
12
[unit: mm]
Power Cable Connector
Signal Cable Connector
For environmental conditions regarding space when placing the Controller on the base
table, refer to the controller manual.
WARNING
■
To ensure safety, a safeguard must be installed for the robot system.
For details on the safeguard, refer to the User’s Guide.
)
NOTE
Summary of Contents for E2C Series
Page 1: ...SCARA ROBOT E2C series MANIPULATOR MANUAL Rev 6 EM069R1409F ...
Page 2: ...MANIPULATOR MANUAL E2C series Rev 6 ...
Page 8: ...vi E2C Rev 6 ...
Page 14: ......
Page 82: ......
Page 92: ...Maintenance 2 General Maintenance 80 E2C Rev 6 ...
Page 118: ...Maintenance 4 Replacing the Cable Unit 106 E2C Rev 6 ...
Page 194: ...Maintenance 11 Replacing the Signal Relay Board 182 E2C Rev 6 ...