background image

ISSUED: 02-13-08  SHEET #:128-9030-2  07-16-08

3 of 6

Visit  the  Peerless  Web  Site  at  www.peerlessmounts.com

For Technical Support Contact Peerless Mounts at 1-800-729-0307 or 708-865-8870.

A1

NOTE: 

Some parts may appear slightly different than illustrated.

Before you begin, make sure all parts shown are included with your product.

D

B

C

A

L

K

F

M

AA

BB

CC

IMPORTANT PRE-ASSEMBLY INFORMATION: 

Ceiling Trays (

A

), and (

A1

) are designed to fit within or above a

24" (610 mm) x 24" (610 mm) section of a conventional suspended ceiling system. It may also be mounted within or
above 24" x 48" conventional suspended ceiling. Ceiling runners (see 

DETAIL 1, page 5

) should have a "T" cross

section and a minimum height of 1.5" (38 mm).

For certain installations it may be best to install ceiling anchors (

step 2

) before installing the ceiling tray (

step 1

).

Description

Qty. Part # 

A

ceiling tray

1

128-2198

A1

filler tray

1

128-2207

B

1/4"-20 x 3/8" screws

4

520-2015

C

1/4"-20 nuts

4

530-9302

D

allen wrench

1

560-9706

F

turnbuckle

4

560-9620

G

12 gauge x 20' (6.1m) tie wire (not shown)

1

600-2008

K

eye bolt

5

580-0006

L

concrete anchor

5

580-0005

M

flush mount tube 

1

1446-014

AA

M5 x 10 mm socket screw

4

520-1216

BB

nut

4

530-9409

CC

3 mm allen wrench

1

560-0194

Parts List

Summary of Contents for ELPMBP02 - False Ceiling Plate

Page 1: ...ualified professional installer R Installation and Assembly False Ceiling Plate Kit 3215 W North Ave Melrose Park IL 60160 800 865 2112 or 708 865 8870 Fax 708 865 2941 www peerlessmounts com Maximum UL Load Capacity 50 lb 22 6 kg Manufactured by Peerless Industries Inc ...

Page 2: ...combined load of the equipment and all attached hard ware and components Never exceed the Maximum UL Load Capacity If mounting to wood joists or wood beam ceilings make sure that mounting screws are anchored into the center of the joists or beams Use of an edge to edge stud finder is highly recommended Always use an assistant or mechanical lifting equipment to safely lift and position equipment Ti...

Page 3: ...ystem It may also be mounted within or above 24 x 48 conventional suspended ceiling Ceiling runners see DETAIL 1 page 5 should have a T cross section and a minimum height of 1 5 38 mm For certain installations it may be best to install ceiling anchors step 2 before installing the ceiling tray step 1 Description Qty Part A ceiling tray 1 128 2198 A1 filler tray 1 128 2207 B 1 4 20 x 3 8 screws 4 52...

Page 4: ...d M5 nuts BB to attach ceiling tray A to filler tray A1 in place of fasteners 1 4 20 x 3 8 screws B and 1 4 20 nuts C if neces sary Tighten M5 x 10 mm socket screws AA using 3 mm allen wrench CC Attaching Ceiling Tray to Filler Tray A F A A1 C or BB B or AA Gray rectangles show correct positions for turnbuckles F A A1 For Mounting Above Ceiling Tile Place ceiling tray A in grid above 24 x 24 or 24...

Page 5: ...en the true ceiling and suspended ceiling is more than 36 914 mm additional wire 12 gauge annealed steel black will be needed VARIOUSANCHORING METHODS Wood Joists or Beams Drill 5 32 4 mm dia holes 2 51 mm deep Fully insert eye bolts K Solid Concrete Drill 1 4 6 mm dia holes 1 5 38 mm deep Hammer in ConcreteAnchor L using Rawl 3250 setting tool or equivalent K L Truss Ceiling No anchor required Af...

Page 6: ...DXWKRUL HG IRU VXFK VHUYLFH RU UHSDLUV E 3HHUOHVV QGXVWULHV QF E WKH IDLOXUH WR XWLOL H SURSHU SDFNLQJ ZKHQ UHWXUQLQJ WKH SURGXFW F LQFRUUHFW LQVWDOODWLRQ RU WKH IDLOXUH WR IROORZ 3HHUOHVVҋ LQVWUXFWLRQV RU ZDUQLQJV ZKHQ LQVWDOOLQJ XVLQJ RU VWRULQJ WKH SURGXFW RU G PLVXVH RU DFFLGHQW LQ WUDQVLW RU RWKHUZLVH LQFOXGLQJ LQ FDVHV RI WKLUG SDUW DFWLRQV DQG IRUFH PDMHXUH Q QR HYHQW VKDOO 3HHUOHVV EH OLDE...