Cut tie wire (

G

) into four pieces of equal length.  Insert wires through the ends of the turnbuckles and loop to prevent

the wire from slipping.  Twist each wire around itself at least six times as tightly as possible.

Drill holes for four ceiling anchors (see “Various Anchoring Methods”). Position the holes so when the tie wires are
attached and taut the optimal angle is 15° (see figure 3.1 for reference). Unit may be mounted at an angle up to 45°
if necessary.

Pull tie wires tight and loop through turnbuckles of the ceiling anchors (or truss).  Again twist each wire around itself
at least six times as tightly as possible.

When this step is complete, the weight of the ceiling tray should be supported by the tie wires.

NOTE: 

20' (6.1 m) of tie wire (

G

) is provided. If space between the true ceiling and suspended ceiling is more than 36"

(914 mm), additional wire (12 gauge annealed, steel, black) will be needed.

VARIOUS ANCHORING METHODS

Wood Joists or Beams

Drill 5/32" (4 mm) dia.
holes 2" (51 mm) deep.
Fully insert eye bolts (

K

).

Solid Concrete

Drill 1/4" (6 mm) dia. holes 1.5" (38 mm) deep.
Hammer in Concrete Anchor (

L

) using Rawl

#3250 setting tool or equivalent.

K

L

Truss Ceiling

No anchor required.  After
attaching tie wire to turnbuckle
loop upper end around ceiling
truss. Pull tie wire tight and
twist it around itself at least six
times as tightly as possible..

A

G

G

G

G

Knockout panels are
provided for electrical outlet
boxes and antenna leads.

A1

Suspended Ceiling Kit installation is now complete.
After all components (Projector Mount, Extension
Column, etc.) and equipment have been attached,
tension the tie wires by adjusting turnbuckles (

F

).

Load must be carried by tie wires - not
suspended ceiling runners

.

• Installer must verify that the ceiling will safely

support four times the combined weight of all
attached equipment and hardware.

• Never attach hooks to filler tray.

WARNING

15°

fig. 3.1

3

3-1

Anchoring Methods

2"

2"

1.5"

CEILING

RUNNER

DETAIL 1

Summary of Contents for ELPMBP02 - False Ceiling Plate

Page 1: ...ualified professional installer R Installation and Assembly False Ceiling Plate Kit 3215 W North Ave Melrose Park IL 60160 800 865 2112 or 708 865 8870 Fax 708 865 2941 www peerlessmounts com Maximum UL Load Capacity 50 lb 22 6 kg Manufactured by Peerless Industries Inc ...

Page 2: ...combined load of the equipment and all attached hard ware and components Never exceed the Maximum UL Load Capacity If mounting to wood joists or wood beam ceilings make sure that mounting screws are anchored into the center of the joists or beams Use of an edge to edge stud finder is highly recommended Always use an assistant or mechanical lifting equipment to safely lift and position equipment Ti...

Page 3: ...ystem It may also be mounted within or above 24 x 48 conventional suspended ceiling Ceiling runners see DETAIL 1 page 5 should have a T cross section and a minimum height of 1 5 38 mm For certain installations it may be best to install ceiling anchors step 2 before installing the ceiling tray step 1 Description Qty Part A ceiling tray 1 128 2198 A1 filler tray 1 128 2207 B 1 4 20 x 3 8 screws 4 52...

Page 4: ...d M5 nuts BB to attach ceiling tray A to filler tray A1 in place of fasteners 1 4 20 x 3 8 screws B and 1 4 20 nuts C if neces sary Tighten M5 x 10 mm socket screws AA using 3 mm allen wrench CC Attaching Ceiling Tray to Filler Tray A F A A1 C or BB B or AA Gray rectangles show correct positions for turnbuckles F A A1 For Mounting Above Ceiling Tile Place ceiling tray A in grid above 24 x 24 or 24...

Page 5: ...en the true ceiling and suspended ceiling is more than 36 914 mm additional wire 12 gauge annealed steel black will be needed VARIOUSANCHORING METHODS Wood Joists or Beams Drill 5 32 4 mm dia holes 2 51 mm deep Fully insert eye bolts K Solid Concrete Drill 1 4 6 mm dia holes 1 5 38 mm deep Hammer in ConcreteAnchor L using Rawl 3250 setting tool or equivalent K L Truss Ceiling No anchor required Af...

Page 6: ...DXWKRUL HG IRU VXFK VHUYLFH RU UHSDLUV E 3HHUOHVV QGXVWULHV QF E WKH IDLOXUH WR XWLOL H SURSHU SDFNLQJ ZKHQ UHWXUQLQJ WKH SURGXFW F LQFRUUHFW LQVWDOODWLRQ RU WKH IDLOXUH WR IROORZ 3HHUOHVVҋ LQVWUXFWLRQV RU ZDUQLQJV ZKHQ LQVWDOOLQJ XVLQJ RU VWRULQJ WKH SURGXFW RU G PLVXVH RU DFFLGHQW LQ WUDQVLW RU RWKHUZLVH LQFOXGLQJ LQ FDVHV RI WKLUG SDUW DFWLRQV DQG IRUFH PDMHXUH Q QR HYHQW VKDOO 3HHUOHVV EH OLDE...

Reviews: