4. Troubleshooting (DeviceNet)
(2) Select the
DeviceNet (Scanner)
tab. The window changes as shown below.
MAC ID
: MAC ID specified for the scanner board
Module/NetWork LED :
Network Status (NS) LED status
IO LED
: Module Status (MS) LED status
applicomR Status
: Scanner board status
The scanner board status is shown in the “Code No. => Comment” form. The
code numbers are shown in the following table.
Status Code
General Protocol
Descriptions
0
No fault detected. The function was performed
correctly.
4
Inaccessible
data.
Additional information:
The remote device is in error.
Check its status.
32
Indicates that the parameters passed to the functions
are not correct (eg: Number of requested variables
too large)
33
Response time-out fault.
Additional information:
The device does not answer. Check its status and the
wiring.
The DeviceNet master has no device to be scanned in
its configuration.
34
Physical defect on the line.
Additional information:
No +24V power supply was detected.
The CAN component of the applicomIO® interface
is "Bus Off".
Check the network wiring and Baud Rate.
36
Device not configured.
Define the device configuration with the
applicomIO® Console and re-initiate the
initialization of the applicomIO® product by running
the PcInitIO
108
Fieldbus I/O Rev.6
Summary of Contents for EM07ZS1647F
Page 1: ...Rev 6 EM07ZS1647F EPSON RC Option Fieldbus I O ...
Page 2: ...E PSON RC Option Fieldbus I O Rev 6 ...
Page 8: ...vi Fieldbus I O Rev 6 ...
Page 12: ...Table of Contents x Fieldbus I O Rev 6 ...
Page 80: ...2 Installation 68 Fieldbus I O Rev 6 ...
Page 88: ...3 Operation 76 Fieldbus I O Rev 6 ...
Page 164: ...5 Maintenance Parts List 152 Fieldbus I O Rev 6 ...
Page 168: ...Appendix A applicomIO Upgrade 156 Fieldbus I O Rev 6 ...