2. Installation
2.3 How to Setup a PROFIBUS DP Network
The following is a basic procedure for setting up a PROFIBUS DP network:
1. Choose station distribution and distribution route on your network.
For details, refer to the following section
2.4 PROFIBUS DP Network Construction
.
2. Choose
baud
rate.
Choose the baud rate based on the network length. Select the fastest baud rate
allowed for the length. Increasing network load due to slow baud rate may cause
trouble including communication failure.
3. Lay
cables.
For details, refer to the following section
2.4 PROFIBUS DP Network Construction
.
4. Configure
stations.
For details, refer to respective manuals of your desired stations.
5. Turn ON the stations.
6. Install the scanner board in your controller.
Refer to the section
2.8 PROFIBUS DP Board Installation
later in this chapter.
7. Configure a master and slaves.
Use the configuration management software for configuring a master and slaves
(scan list). For details, please refer to the configuration management software
manual.
To configure EPSON RC+ as a master, refer to the section
2.8 PROFIBUS DP Board
Installation
later in this chapter.
8. Configure EPSON RC+.
Refer to the section
2.10 EPSON RC+ Fieldbus I/O Installation
later in this chapter.
9. Operate the PROFIBUS DP network.
Fieldbus I/O Rev.6
19
Summary of Contents for EM07ZS1647F
Page 1: ...Rev 6 EM07ZS1647F EPSON RC Option Fieldbus I O ...
Page 2: ...E PSON RC Option Fieldbus I O Rev 6 ...
Page 8: ...vi Fieldbus I O Rev 6 ...
Page 12: ...Table of Contents x Fieldbus I O Rev 6 ...
Page 80: ...2 Installation 68 Fieldbus I O Rev 6 ...
Page 88: ...3 Operation 76 Fieldbus I O Rev 6 ...
Page 164: ...5 Maintenance Parts List 152 Fieldbus I O Rev 6 ...
Page 168: ...Appendix A applicomIO Upgrade 156 Fieldbus I O Rev 6 ...