2. Installation
2.9 EtherNet/IP Board Installation
Following two board types can be used for the fieldbus I/O option EtherNet/IP.
- PCU-ETHIO
2.9.1 Board Appearance
Part names and functions of the scanner board are shown in the following figure. For details
of the status display LEDs, refer to the
4.
Troubleshooting
in this manual.
PCU-ETHIO
C0 C1 C2
JP1
JP1
0
1
D-Sub 9 pin
(Not in use)
Status Display LED (2)
EtherNetI/P Connector
4-pin Terminal
Watchdog Port
(Do not use this port.)
Jumper for Board Address
LED (2)
(Not in use)
2.9.2 Specifications
Part Number
applicom PCU-ETHIO
Modes Master/Slave
Baud Rates
10, 100 Mbps
Interface EtherNet/IP
1
port
Maximum Node
127
Connection Type
Cyclic, Change of State
Explicit messaging
Yes
EDS support
Yes
Input Data Size
1 to 505 bytes
Output Data Size
1 to 509 bytes
Automatic Detection
Yes. Devices can be detected automatically.
54
Fieldbus I/O Rev.6
Summary of Contents for EM07ZS1647F
Page 1: ...Rev 6 EM07ZS1647F EPSON RC Option Fieldbus I O ...
Page 2: ...E PSON RC Option Fieldbus I O Rev 6 ...
Page 8: ...vi Fieldbus I O Rev 6 ...
Page 12: ...Table of Contents x Fieldbus I O Rev 6 ...
Page 80: ...2 Installation 68 Fieldbus I O Rev 6 ...
Page 88: ...3 Operation 76 Fieldbus I O Rev 6 ...
Page 164: ...5 Maintenance Parts List 152 Fieldbus I O Rev 6 ...
Page 168: ...Appendix A applicomIO Upgrade 156 Fieldbus I O Rev 6 ...