2. Installation
(9) The default slave EDS file is created.
The path is: C:\Program Files\Woodhead\Direct-link\ApplicomIO2.3\ConfigIO
\Config01\applicomio.eds.
You may make a copy of the default slave EDS file and modify it to create your
original EDS file if necessary.
Edit the copy of the slave EDS file using Notepad. You may want to change the
VendName and ProductTypeStr.
Copy the EDS file to the system where the master is located. Add the new slave
device to the master using the new EDS file.
(10) On the master system, scan the network for new devices. The new slave device
should be detected.
Use the EDS file created in previous steps for the slave device.
66
Fieldbus I/O Rev.6