Maintenance
Maintenance
User’s Guide
PROCEDURE
Turn the projector's power off, then disconnect the
power cable.
Wait until the lamp has cooled down, and then
remove the lamp cover from the base of the projector.
It takes about one hour after the power has been turned off for
the lamp to be cool enough.
Use the screwdriver that is supplied with the spare lamp or
your own cross head screwdriver to loosen the lamp cover
fixing screw at the side of the projector.
Slide the lamp cover straight, and then lift up the lamp cover to
remove it.
Replacing the Lamp
When replacing the lamp because it has stopped illuminating,
there is a possibility that the lamp may be broken.
If replacing the lamp of a projector which has been installed
on the ceiling, you should always assume that the lamp is
broken, and you should stand to the side of the lamp cover, not
underneath it. Remove the lamp cover gently. Small pieces of
glass may fall out when the lamp cover is opened. If pieces of
glass get into your eyes or mouth, seek medical advice
immediately.
Warning
Wait until the lamp has cooled down sufficiently before
removing the lamp cover. If the lamp is still hot, burns or other
injuries may result. It takes about one hour after the power has
been turned off for the lamp to be cool enough.
Caution