3.2.2.12 Fusing Unit Removal
1.
1.
Open the top cover. Remove the imaging cartridge. Cover the imaging cartridge to protect it
from light or place it in a dark area.
2.
Remove the main controller board. (Refer to Section 3.2.1.1.)
3.
3.
Loosen two CC (M3x8) screws which secure the right cover.
4.
Release left and right tabs of the top cover from the printer base unit then remove the top
cover.
5.
Remove one CC (M3x6) screw on the fusing unit cover and remove the fusing unit cover.
6.
Disconnect two connectors for the thermistor and the fusing unit lamp.
7.
Remove two CP(O) (M3x6) screws on the fusing unit then remove the fusing unit.
3.2.2.13 Paper Exit Sensor Removal
1.
Remove the fusing unit. (Refer to Section 3.2.2.12.)
2.
Remove the paper exit sensor.
3.
Disconnect the paper exit sensor from connector of the cable.
Connector for
Thermistor
Connector for Lamp
CP(O)(M3X8)
CP(O)(M3X8)
Fusing Unit
Figure 3-25. Fusing Unit Removal
Paper Exit Sensor
Connector
Figure 3-26. Paper Exit Sensor Removal
EPL-N1200 Service Manual
Disassembly and Assembly
Rev. A
3-21