6.2.1.2 Electrical Components Layout
Figure 6-12. Electrical Component Layout - Duplex Unit
6.2.2 Mechanical Operations
6.2.2.1 Switchback Mechanism
Switchback operation
The Eject Roller reverses the direction of feeding the 1-sided print
into the Duplex Unit (switchback operation). This switchback
operation by the Eject Roller is accomplished by changing the
direction of rotation of the Switchback Motor whose drive is
transmitted via a gear train.
Figure 6-13. Switchback Mechanism
switchback Motor (M1)
Transport Motor
Control Board (PWB-A)
Transport Sensor
Door Set Sensor
To the Duplex Unit
Eject Roller
Eject Sensor (PC3)