GENERAL DESCRIPTION
Rev. A
1-
7
1.3 INTERFACES
This scanner is equipped with either a bi-directional parallel interface (Bi-D model) or a SCSI (SCSI
model). This section presents the specifications for each interface type.
1.3.1 Bi-D Parallel Interface
Data transmission mode:
8-bit parallel
Synchronization:
/STROBE pulse
Handshaking:
BUSY and /ACK handshaking
Signal Level:
TTL-level compatible
Data transmission timing:
Refer to Figures 1-4 and 1-5.
Connector type:
57-30360 (AMPHENOL) 36-pin plug or equivalent
(Refer to Figure 1-6.)
Connector pin assignments:
Refer to Table 1-2.
Figure 1-4. Data Transfer Timing (Host to Scanner)
Figure 1-5. Data Transfer Timing (Scanner to Host)
Figure 1-6. Applicable Connector
Summary of Contents for FILMSCAN 200
Page 1: ...EPSON FILM SCANNER FilmScan 200 SERVICE MANUAL SEIKO EPSON CORPORATION 4007375 ...
Page 5: ...v REVISION SHEET Revision Issued Data Contents Rev A FEBRUARY 28 1997 First issue ...
Page 8: ...EPSON SEIKO EPSON CORPORATION ...
Page 75: ...CHAPTER 4 ADJUSTMENT No adjustment is required in this product ...
Page 85: ...CHAPTER 6 MAINTENENCE 6 1 MAINTENENCE 6 1 6 2 LUBRICATION 6 1 ...
Page 86: ...APPENDIX A 1 CONNECTOR PIN ASSIGNMENTS 1 A 2 EXPLOED DIAGRAM 8 ...
Page 88: ...FilmScan 200 Rev A A 2 Figure A 2 Cable Connection SCSI Model ...
Page 95: ...APPENDIX Rev A A 9 Figure A 4 FilmScan 200 Bi D Model Exploded Diagram 2 2 ...
Page 96: ...FilmScan 200 Rev A A 10 Figure A 5 FilmScan 200 SCSI Model Exploded Diagram 1 2 ...
Page 97: ...APPENDIX Rev A A 11 Figure A 6 FilmScan 200 SCSI Model Exploded Diagram 2 2 ...
Page 98: ...FilmScan 200 Rev A A 12 Figure A 7 APS Holder option Exploded Diagram ...
Page 100: ...FilmScan 200 Rev A 6 2 Shaft 1 G 36 1 G 36 Figure 6 1 Lubrication Points ...