DISASSEMBLY AND ASSEMBLY
Rev. A
3-7
.
3.2.4 Inverter Board and Lamp Unit Removal
Inverter Board
Step 1:
Remove the upper case (Refer to section 3.2.2.)
Step 2:
Disconnect the FFC cable from the inverter board.
Step 3:
Remove the three white CB (M3 x 6) screws that fastens on the inverter board then remove
the inverter board.
Lamp Unit
Step 1:
Remove the inverter board (Refer to above.).
Step 2:
Remove the black screw that fastens the lamp unit and the inverter board.
Step 3:
Disconnect the lamp unit which is fixed by two connectors to the inverter board.
FFC Cable
Inverter Board
Figure 3-5. Inverter Board and Lamp Unit Removal
Lamp Unit
Inverter
Board
Figure 3-6. Lamp Unit Removal
Summary of Contents for FILMSCAN 200
Page 1: ...EPSON FILM SCANNER FilmScan 200 SERVICE MANUAL SEIKO EPSON CORPORATION 4007375 ...
Page 5: ...v REVISION SHEET Revision Issued Data Contents Rev A FEBRUARY 28 1997 First issue ...
Page 8: ...EPSON SEIKO EPSON CORPORATION ...
Page 75: ...CHAPTER 4 ADJUSTMENT No adjustment is required in this product ...
Page 85: ...CHAPTER 6 MAINTENENCE 6 1 MAINTENENCE 6 1 6 2 LUBRICATION 6 1 ...
Page 86: ...APPENDIX A 1 CONNECTOR PIN ASSIGNMENTS 1 A 2 EXPLOED DIAGRAM 8 ...
Page 88: ...FilmScan 200 Rev A A 2 Figure A 2 Cable Connection SCSI Model ...
Page 95: ...APPENDIX Rev A A 9 Figure A 4 FilmScan 200 Bi D Model Exploded Diagram 2 2 ...
Page 96: ...FilmScan 200 Rev A A 10 Figure A 5 FilmScan 200 SCSI Model Exploded Diagram 1 2 ...
Page 97: ...APPENDIX Rev A A 11 Figure A 6 FilmScan 200 SCSI Model Exploded Diagram 2 2 ...
Page 98: ...FilmScan 200 Rev A A 12 Figure A 7 APS Holder option Exploded Diagram ...
Page 100: ...FilmScan 200 Rev A 6 2 Shaft 1 G 36 1 G 36 Figure 6 1 Lubrication Points ...