Maintenance 4. Cable
130
G10 / G20 Rev.20
(7) Connect the air tubes, D-sub cable, and connectors to the connector plate (inner side).
D-sub cable
Air tube
Connector
Nut
Connector plate
Ground
terminal
Plain
washer
Spring washer
D-sub
(8) Loosely mount the connector plate with 2 screws (M4).
For details, refer to
Maintenance: 3.4 Connector Plate
.
(9) Disconnect the Arm #2 side cables to the lower
part of Arm #1 and pull the cables into Arm #2.
Cable
(10) Mount the spring for cable protection to the spring
plate with a wire tie.
Secure the spring plate to Arm #2.
Wire tie
Spring plate
Spring
2-M4
×
8
G10
G20
(11) Move Arm #2 until the arm touches the
mechanical stop to make allowance (push the
cables toward the spring by approx. 20 mm).
Then, band the cables and air tubes with a wire tie.
If you band the cables and tubes without
allowance, the cables are pulled and may be
disconnected during the robot operation. Make
sure to make allowance.
Wire tie
G10
G20
(12) Remove the plastic bags on the Arm side applied in step (2).
NOTE