Maintenance 7. Arm #3
128
G3 Rev.14
(12) Connect the backup connectors for Joint #3 and #4 (X63, X64) to the battery board.
Bundle the backup cable with wire tie to prevent the cable connector to fall off by
mistake.
(13) Re-bundle the cables in their original positions with a wire tie removed in step (5).
Do not allow unnecessary strain on the cables.
(14) Install the arm top cover and the arm bottom cover.
For details, refer to
Maintenance: 3. Covers
.
(15) Perform the calibration of Joint #3 and #4.
For details, refer to
Maintenance: 14. Calibration
.