Maintenance 8. Arm #4
G3 Rev.14
135
(7) Connect the backup cable of Joint #4: X64.
Bundle the cables with the wire tie to prevent the backup connector from falling off by
mistake.
(8) Mount the battery board to Arm #2.
The screws on the rear side secure both the
battery board and the user plate. Set these
screws when mounting the user plate.
2-M4
×
5
Battery board
2-M4
×
12
(9) Mount the user plate and ground wire to Arm #2.
(10) Re-bundle the cables in their original positions with a wire tie removed in step (6).
Do not allow unnecessary strain on the cables.
(11) Install the arm top cover and the arm bottom cover.
For details, refer to
Maintenance: 3. Covers
.
(12) Perform the calibration of Joint #4.
For details on the calibration method, refer to
Maintenance: 14. Calibration
.