Maintenance 10. Bellows
154
G3 Rev.14
Bellows
Installation
(1) To attach the upper bellows, move the shaft to its lower limit.
To attach the lower bellows, move the shaft to its upper limit.
To move the shaft up/down, press and hold the brake release switch.
Be sure to keep enough space and prevent the end effector hitting any peripheral
equipment.
The brake release switch affects only Joint #3. When the brake release switch is
pressed, the brake for Joint #3 is released simultaneously.
Be careful of the shaft while the brake release switch is being pressed because the
shaft may be lowered by the weight of an end effector.
(2) Pass the shaft through the bellows from the larger joint.
(3) Secure the cover side of the bellows.
The bellows has two joints:
The larger joint must be attached to the cover side.
The smaller joint must be attached to the end face
side of the shaft.
Attach the mounting part of the bellows until the
end touches the cylindrical part of the cover.
Then, secure them with clamp bands.
Upper bellows
cover side
Bottom bellows
cover side
(4) Secure the end face side of the bellows to the shaft.
Cover the bearing case (black) on the end face of
the shaft with the bellows mounting part.
Then, secure them with clamp bands.
Upper bellows
shaft edge
Bottom bellows
Shaft edge
(5) After completing the attachment of the bellows, move the shaft up/down by hand
several times and rotate Joint #4. Make sure that the bellows can expand and
contract smoothly without any excessive force.
(6) Turn OFF the Controller and peripheral equipment.
(7) Attach the end effector.
(8) Connect the wires and tubes to the end effector.
Summary of Contents for G3 Series
Page 1: ...Rev 14 EM183R3623F SCARA ROBOT G3 series MANIPULATOR MANUAL ...
Page 2: ...MANIPULATOR MANUAL G3 series Rev 14 ...
Page 8: ...vi G3 Rev 14 ...
Page 14: ......
Page 84: ...Setup Operation 5 Motion Range 72 G3 Rev 14 ...
Page 86: ...74 ...
Page 200: ...Maintenance 15 Maintenance Parts List 188 G3 Rev 14 ...