Maintenance 7. Arm #3
G6 Rev.21
147
Joint #3 brake
Removal
(1) Turn ON the Controller.
(2) Push down the shaft to its lower limit while pressing the brake release switch. Be
sure to keep enough space and prevent the end effector hitting any peripheral
equipment.
The brake release switch is applied to both Joints #3 and #4. When the brake release
switch is pressed, the respective brakes for Joints #3 and #4 are released
simultaneously. (The brake for Joint #4 is only installed to G6-**3**.)
Be careful of the shaft falling and rotating while the brake release switch is being
pressed because the shaft may be lowered by the weight of an end effector.
(3) Turn OFF the Controller.
(4) Remove the arm top cover and the arm bottom cover.
For details, refer to
Maintenance: 3. Covers
.
(5) Cut off the wire tie used for binding the motor cables to the Joint #3 motor.
(6) Disconnect the following connectors.
Connectors X231, X31 (Hold the claw to remove.)
Connector X32, X63
(7) Remove the Joint #3 motor unit from Arm #2.
4-M4
×
12
+
Washer
Joint #3
motor unit
(8) Remove the Joint #3 motor from the Z plate.
(8) 4-M5
×
12
Joint #3 motor
Z plate
Z1 pulley
Brake hub
(9) 2-M3
×
4
set screw
(9) Remove the brake hub from the Z1 pulley.
(10) Remove the brake from the brake plate.
2-M3
×
10
Brake
Z plate
Brake
plate