Free running distance in emergency
The operating Manipulator cannot stop immediately after the Emergency Stop switch is
pressed.
The free running time, angle, and distance of the Manipulator are shown below.
However, remember that the values vary depending on following conditions.
Weight of the end effector Weight of work piece Operating pose
Weight Speed Accel etc.
Conditions for Measurement
Accel Setting
100
Speed Setting
100
Load [kg]
6
Weight Setting
6
Joint #1
Start point of
operation
Target point
Stop point
Joint #2
Point where the
emergency stop
signal is input
Controller
RC700-A
Manipulator
G6-45***
G6-55***
G6-65***
Free running time
Joint #1 + Joint #2
[s]
0.5
0.5
0.5
Joint #3
[s]
0.4
0.4
0.4
Free running angle
Joint #1
[deg]
35
30
35
Joint #2
[deg]
70
55
70
Joint #1 + Joint #2 [deg]
105
85
105
Free running distance
Joint #3 G6-**1** [mm]
G6-**3**
95
95
95