A3 Size Color Flat Bed Scanner GT-30000
Revision A
DISASSEMBLY & ASSEMBLY
Disassembly Procedures
44
Figure 4-5. Cap Removal
4.2.1.4 Scanner Mechanism Removal
Remove the scanner mechanism from the housing as described below.
1. Remove the scanner mechanism cover. (See "Chapter 4.2.1.3 Mechanism
Cover Removal".)
2. Remove the four screws (No.1) which are securing the scanner
mechanism to the housing, and then hold the scanner mechanism removal
belts to remove the scanner mechanism from the housing.
Figure 4-6. Scanner Mechanism Removal
C H E C K
P O I N T
!
When installing the scanner mechanism:
1. Remove the power switch key from the scanner
mechanism.
2. Install the scanner mechanism to the housing.
3. Re-attach the power switch key.
!
After removing the scanner mechanism, be sure to
place it on top of the special tool (leveling tool) while
working in order to maintain the rigidity of the product.
(See "Chapter 4.2.1.4.1 Using the Leveling Tool".)
Screw Cap
Cross-section
Insert an object with
a sharp tip such as
a needle or gimlet
into the hole to lever
out the cover.
Glass
The belt tightening torque is 50 ± 10 N
•
cm.
Belt
Belt tightening
torque 50 ± 10 N
•
cm
Summary of Contents for GT-30000 Series
Page 9: ...C H A P T E R 1 PRODUCTOUTLINE ...
Page 22: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 29: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 37: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY ...
Page 55: ...C H A P T E R 5 ADJUSTMENTS ...
Page 65: ...C H A P T E R 6 MAINTENANCE ...
Page 67: ...C H A P T E R 7 APPENDIX ...
Page 82: ...Model ES 9000H GT 30000 Board PBA MAIN Rev 1 Sheet 1 3 ...
Page 83: ...Model ES 9000H GT 30000 Board PBA MAIN Rev 1 Sheet 2 3 ...
Page 84: ...Model ES 9000H GT 30000 Board PBA MAIN Rev 1 Sheet 3 3 ...
Page 85: ...Model ES 9000H GT 30000 Board PWS POWER Rev A Sheet 1 1 ...
Page 86: ...Model ES 9000H GT 30000 Board PBA Connect Rev 1 Sheet 1 1 ...