Rev. C
OS and Drivers 3-61
IR-320 Series Technical Reference Manual
1. The following dialog box is displayed if the check mark is removed from the Default item.
2. Each of the items below can be set if
OK
is clicked.
[Stabilization]
Set the jitter correction value within a range of 1 to 20.
The default setting is 1.
The jitter correction takes multiple samplings of the touch panel device’s
coordinate data and calculates the average value to average and thus
stabilize the touch position. The Stabilization setting sets the number of times
coordinate data are sampled.
[Coordinates Data
Sampling Cycle]
This sets the coordinate data sampling interval within a range of 10 to 155 ms.
The default setting is 10. The coordinate data sampling interval sets the time
coordinate data are sent to the system from the touch panel device.
[On]
This sets the tap sound On or Off. The tap sound is output if this item is
checked. The default setting is On.
[Frequency]
This sets the tap sound frequency within a range of 37 to 16383 Hz. Dragging
the slider left or right changes the setting value. The default setting is 600 Hz.
[Port]
This displays the port used. This item cannot be set here.
[IRQ]
This displays the IRQ used. This item cannot be set here.
[I/O Address]
This displays the I/O address used. This item cannot be set here.
Summary of Contents for IR-320
Page 1: ...Technical Reference Manual IR 320 Issued Date Issued by EPSON English 404368102 ...
Page 2: ......
Page 38: ...1 22 IR 320 System Overview Rev C ...
Page 260: ...4 80 Utilities Rev C ...
Page 294: ...5 34 BIOS Functions Rev C ...
Page 308: ...6 14 Device Diagnostics Utility Rev C Confidential ...
Page 324: ...A 4 Wake On LAN Rev C Confidential ...
Page 332: ...B 8 The IR 310 Compared to the IR 320 Rev C ...
Page 339: ......
Page 340: ...EPSON SEIKO EPSON CORPORATION ...