M200 / M205 / M100 / M105 Series
Revision A
Disassembly/Reassembly
Routing FFCs/cables
56
Confidential
2.4 Routing FFCs/cables
ADF Frame Assy / ADF Document Support (M200/M205 Series)
Rotate the grounding wire of the ADF Frame Assy and ADF Document Support(x2) as follows.
Grounding wire of the ADF Frame Assy
Hang the grounding wire the dowel (x3) and route through the hole of the ADF Base.
Grounding wire of the ADF Document Support
1. Route along the rib A of the ADF Base and hang the dowel on the bottom of the ADF Base.
2. Route along the inside the hook and rib B of the ADF Base and route through the hole of the ADF Base.
Grounding wire of the ADF Document Support
ADF Document Support
Bottom
Grounding wire of the ADF Document Support
ADF Base
Rib A
Rib B
Dowel
Hole
Grounding wire of the ADF Frame Assy
Hook
ADF Frame Assy
ADF Document Support
ADF Hinge Left (M200/M205 Series)
Route the grounding wire (x2) of the ADF Frame Assy/ADF Document
Support through the ADF Hinge Left as follows.
1. Route the grounding wire (x2) through the hole (x2) of the ADF Hinge Left.
2. Install the ADF Hinge Left to the ADF Base. Hang the grounding wire
(x2) on the rib (x2) of the ADF Hinge Left and route.
Grounding wire
Hole
ADF Hinge Left
Bottom
Hole
ADF Base
ADF Hinge Left
Rib
ADF/Scanner Unit (M200/M205 Series)
Scanner FFC
Insert the hole of the Housing Left and connect the connector (CN11) of
the Main Board through the ferrite core.
Grounding wire
Insert the hole of the Housing Left and connect the Ribs of Main Board Shield
Plate Sub.
Route the Scanner FFC
inserting the hole of the
Housing Left.
Housing Left
Ribs of Main Board Shield Plate Sub
Ferrite core
Scanner FFC (M200/M205 Series)
Route the Scanner FFC as follows.
1. Insert the Scanner FFC through the hole of the Scanner Housing Lower in the direction shown above, and then secure the FFC with double-sided tape on
position with the standard shown in the figure above.
2. Route the FFC through the ribs (x7) of the Scanner Housing Lower taking care not to damage the FFC.
3. Route the FFC through the ribs (x5) on the bottom of the Scanner Carriage taking care not to damage the FFC.
4. Connect the Scanner FFC to the Relay Board and CIS Module as shown above.
Bottom of Scanner Carriage
Connector of Relay Board
Connector of CIS Module
Standard for attaching double-sided tape
7.5 mm
5 mm
20 mm
Scanner Carriage
Scanner FFC
Hole
Rib
Double-sided tape
Scanner Motor (M200/M205 Series)
Route the Scanner Motor cable through the hooks (x4) of the Scanner Motor as shown above.
Secure the grounding wire of the Relay Board and the Scanner Motor together with the screw as show above.
Relay Board
Scanner Motor cable
C.B.P-TITE SCREW 3x10 F/ZN-3C (5 ± 1 kgf·cm)
Grounding wire
Scanner Motor
Screw it with
grounding terminal
Scanner Motor
Scanner Carriage
Summary of Contents for M200
Page 1: ...SERVICE MANUAL CONFIDENTIAL Color Inkjet Printer M200 M201 M205 M100 M101 M105 SEMF12 012 ...
Page 9: ...Confidential CHAPTER 1 TROUBLESHOOTING ...
Page 18: ...Confidential CHAPTER 2 DISASSEMBLY REASSEMBLY ...
Page 59: ...Confidential CHAPTER 3 ADJUSTMENT ...
Page 73: ...Confidential CHAPTER 4 MAINTENANCE ...