Maintenance 4. Cable
N6 Rev.2
211
(8) Install the cable fixing plate A to Arm #1.
Hexagon socket head cap bolts: 2-M4×8
Tightening torque: 4.0
±
0.2 N·m
Be careful not to tighten the screws with the
cables get caught on the plate.
(9) Pass the cable unit to the Arm #1.
Do not pass the cables forcibly while the
connectors get caught. Doing so may result
in disconnection of the cables or breakage of
the connectors.
(10) Pass the cables (connectors) through the hole
on the end of the Arm #1
Cables (connectors):
BAT_CN3, BAT_CN6
GS01,
LED_CN1
(11) Connect the connectors to the board.
Cables (connectors):
BAT_CN3, BAT_CN6
LED_CN1
NOTE
NOTE