Maintenance 5. Actuator Units
N6 Rev.2
267
5.1.1 Joint #1 (N6-A1000*): Cable direction: Standard (backward)
Removal
Joint #1
Actuator Unit
N6-A1000*
Cable direction:
Standard
(backward)
(1) Remove the covers.
Base cover, Joint #1 cover, and Joint #1 inside cover
For details, refer to
Maintenance 3. Covers.
(2) Remove the Arm #1 outside cover.
Hexagon socket head cap bolts:
8-M5×20 (with plain washer)
8-M5
×
20 (with plain washer)
Arm #1 outside cover
(3) Remove the cable unit inside the Joint #1.
For details, refer to the Removal steps (7), (47) through (56), and (58) in
Maintenance 4.1 Cable Unit (N6-A1000*): Cable direction Standard
(backward).
(4) Disconnect the M/C cable.
For details, refer to
Maintenance 4.6. M/C Cable
(5) Lay down the Manipulator.
Be sure to have at least 2 people to lay down the Manipulator.
(6)
Remove the base bottom plate.
Hexagon socket head cap bolts: 4-M4×8
(7)
Remove the base.
Hexagon socket head cap bolts:
8-M6×40 (with plain washer)
When you remove it, be careful not to catch
the cables on the Joint #1 actuator unit.
8-M6
×
40 (with plain washer)
NOTE
NOTE
Summary of Contents for N6 Series
Page 1: ...Rev 2 EM187R3735F 6 Axis Robots N6 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual N6 series Rev 2 ...
Page 8: ...vi N6 Rev 2 ...
Page 14: ......
Page 27: ...Setup Operation 1 Safety N6 Rev 2 15 N6 A850 R C A D F G F E H G F B G F G F F F N6 A850 BR F ...
Page 34: ...Setup Operation 2 Specifications 22 N6 Rev 2 N6 A850 BR Cable direction Upward ...
Page 52: ...Setup Operation 3 Environment and Installation 40 N6 Rev 2 N6 A850 R Maximum motion range 802 ...
Page 66: ...Setup Operation 4 End Effectors 54 N6 Rev 2 N6 A850 R Unit mm ...
Page 104: ......
Page 274: ...Maintenance 4 Cable 262 N6 Rev 2 4 7 1 Signal Power cable ...
Page 275: ...Maintenance 4 Cable N6 Rev 2 263 ...
Page 276: ...Maintenance 4 Cable 264 N6 Rev 2 4 7 2 User Cable ...