(5) Install the base bottom plate.
Hexagon socket head cap bolts: 4-M4×8
Tightening torque: 4.0
±
0.2 N·m
Be careful not to catch the cables.
(6) Install the cable unit inside the Joint #1.
For details, refer to the Removal steps (4) through (8), (56) through (64), and (66)
in
Maintenance 4.3 Cable Unit (N6-A850*R): Cable direction Standard
(backward).
(7) Install the following covers:
Base cover, Joint #1 cover, and Joint #1 inside cover
For details, refer to
Maintenance 3. Covers.
(8) Disconnect the M/C cable.
For details, refer to
Maintenance 4.6. M/C Cable.
(9) Perform calibration for the Joint #1.
For details, refer to
Maintenance 8. Calibration.