Figure 3-3. The Carriage Unit does not operate.
Figure 3-4. The Fluorescent Lamps are not lit.
Has the Carriage
Lock been
released?
Is the Housing
Upper installed
correctly?
Is the Connector
CN1 on the Main
Board connected?
Is the Harness
connected to the
Main Board and
Carriage?
Is the Carriage
Moving Mechanism
without problem?
Start
Release the
Carriage Lock.
Install it normally.
Connect the
Connector.
Connect the
Harness.
Replace the CR
Motor.
Can the CR Motor
operate normally?
Replace the Main
Board.
Re-disassemble and
re-assemble.
Replace the
corresponding part.
Is the Connector
CN1 connected to
the Main Board?
Are the Connectors
CN1, CN2 on the
CCD Board
connected?
Are the Fluorescent
Lamps set on the
Inverter Board
securely?
Is the Harness
connected to the
Main Board and
Carriage?
Start
Connect the
Connector.
Connect the
Connectors.
Re-set them on the
Inverter Board.
Replace the
Carriage.
Replace the Main
Board.
Summary of Contents for Perfection4180 Photo
Page 5: ...Revision Status Revision Date of Issue Description A July 30 2004 First release ...
Page 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 19: ...C H A P T E R 2 OPERATING PRINCIPLES ...
Page 23: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 29: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY ...
Page 52: ...C H A P T E R 5 ADJUSTMENT ...
Page 54: ...C H A P T E R 6 MAINTENANCE ...
Page 57: ...C H A P T E R 7 APPENDIX ...
Page 66: ...401 GT F600 PERFECTION 4180 PHOTO NO 1 Rev 01 B170 ACCE 001 10 20 30 40 402 400 ...