Maintenance 1. Safety Precautions on Maintenance
108
RC420 Rev.9
■
Make sure that the power rating (wattage) of a new Motor Driver module is
correct. Using a Motor Driver module with improper power rating (wattage) in
the Controller may not only cause improper function of the robot system but also
damage to the system.
CAUTION
■
The serial number of the Manipulator that should be connected is indicated on
the Connection Check Label on the Controller. Connect the Controller and the
Manipulator correctly. Improper connection between the Controller and the
Manipulator may cause not only improper function of the robot system but also
serious safety problems.
Before performing maintenance on the Controller, all the data must be copied as a backup.
The details of data backup/restore are described in the Maintenance
2.5Backup of Data
1.2 Lockout
The lockout is a method to prevent any one from turning ON the robot system by mistake
while someone else is within the safeguarded area for maintenance or repair.
When the robot system is locked out, the POWER switch of the Controller is locked in the
OFF position. The procedure for lockout is shown below.
(1) Turn OFF the Controller.
(2) Tilt the lockout metal hasp in the direction of the arrow indicated below.
Lockout metal hasp
(3) Close the front door while the metal hasp comes out as shown below.
Lockout metal hasp
1.3 Tagout
The tagout method is attaching a tag or sign plate to the Power switch to prevent any one from
turning ON the robot system by mistake while someone else is within the safeguarded area for
maintenance or repair.
)
NOTE
Summary of Contents for RC420
Page 1: ...Rev 9 EM073C1492F ROBOT CONTROLLER RC420 ...
Page 2: ...ROBOT CONTROLLER RC420 Rev 9 ...
Page 12: ...Setup Operation ...
Page 20: ...Setup Operation 1 Safety 10 RC420 Rev 9 ...
Page 30: ...Setup Operation 2 3 Controller Part Names and Functions 20 RC420 Rev 9 ...
Page 50: ...Setup Operation 5 5 Circuit Diagrams EMERGENCY Connector 40 RC420 Rev 9 ...
Page 58: ...Setup Operation 6 3 Pin Assignments STANDARD I O Connector 48 RC420 Rev 9 ...
Page 114: ...Setup Operation 10 UPS Uninterruptible Power Supply 104 RC420 Rev 9 ...
Page 115: ...97 Maintenance This manual contains maintenance procedures for the RC420 Robot Controller ...
Page 116: ...Maintenance RC420 Rev 9 106 ...
Page 138: ...Maintenance 6 Motor Driver Module 128 RC420 Rev 9 ...
Page 170: ...Maintenance 12 Recovering the HDD 160 RC420 Rev 9 ...