Setup & Operation 4. OPTIONAL DEVICE Connector
RC420 Rev.9
31
4.3 OPTIONAL DEVICE Dummy Plug
The OPTIONAL DEVICE Dummy Plug is connected to the OPTIONAL DEVICE
connector when an operation unit or ATTEND (TEACH) control device is not used.
When manufacturing robotic systems without using the operation unit or ATTEND
(TEACH) control device, you can use the dummy plug, as shown below, to disable the
Emergency Stop input for the OPTIONAL DEVICE port, and the ATTEND (TEACH)
control device enable/disable input.
In this case, however, you cannot operate the Manipulator while the safety door is open.
When designing and manufacturing robotic systems, follow the descriptions of the
Safety
chapter in EPSON RC+ User’s Guide.
OPTIONAL DEVICE
OPTIONAL DEVICE Dummy Plug
Connector
E_SW11
E_SW21
E_SW12
E_SW22
SG
ENABLE
SG
KEY2
6
9
10
11
13
14
15
19
Connector Standard
OPTIONAL DEVICE Dummy Plug
D-sub 25 pin
#4-40 screw
Summary of Contents for RC420
Page 1: ...Rev 9 EM073C1492F ROBOT CONTROLLER RC420 ...
Page 2: ...ROBOT CONTROLLER RC420 Rev 9 ...
Page 12: ...Setup Operation ...
Page 20: ...Setup Operation 1 Safety 10 RC420 Rev 9 ...
Page 30: ...Setup Operation 2 3 Controller Part Names and Functions 20 RC420 Rev 9 ...
Page 50: ...Setup Operation 5 5 Circuit Diagrams EMERGENCY Connector 40 RC420 Rev 9 ...
Page 58: ...Setup Operation 6 3 Pin Assignments STANDARD I O Connector 48 RC420 Rev 9 ...
Page 114: ...Setup Operation 10 UPS Uninterruptible Power Supply 104 RC420 Rev 9 ...
Page 115: ...97 Maintenance This manual contains maintenance procedures for the RC420 Robot Controller ...
Page 116: ...Maintenance RC420 Rev 9 106 ...
Page 138: ...Maintenance 6 Motor Driver Module 128 RC420 Rev 9 ...
Page 170: ...Maintenance 12 Recovering the HDD 160 RC420 Rev 9 ...