Functions 14. Option Slots
156
RC700-D Rev.2
(4)
Shield Configuration
“Frame Ground” and “User Ground” of the shield: CN4, CN5, CN6, and CN7
1-2 pin short
: Frame ground (FG) shield configuration.
When you want to spread the shield noise to the robot
Controller side.
2-3 pin short
: User ground (UG) shield configuration.
When you want to insulate the shield by external connection
device and robot Controller.
Or when you want to spread the shield noise to the external
connection device side.
User Ground (UG): Analog ground (AGND) on the external connection device side.
Frame Ground (FG): Digital ground (DGND) inside the robot Controller.
Channel
Configuration
CN4
CN5
CN6
CN7
DAC1ch
FG Shield*
1-2 short
Not Use
Not Use
Not Use
UG Shield
2-3 short
DAC2ch
FG Shield *
Not Use
1-2 short
Not Use
Not Use
UG Shield
2-3 short
ADC1ch
FG Shield *
Not Use
Not Use
1-2 short
Not Use
UG Shield
2-3 short
ADC2ch
FG Shield *
Not Use
Not Use
Not Use
1-2 short
UG Shield
2-3 short
*: Default
14.6.3 Confirmation with EPSON RC+ (Analog I/O Board)
The Controller software automatically identifies the analog I/O board when mounting
analog I/O board to the optional unit of the Controller. Therefore, no software
configuration is needed.
Correct identification can be confirmed from EPSON RC+.
(1)
Select the EPSON RC+ 7.0 menu-[Setup]-[System Configuration] to display the
[System Configuration] dialog.
(2)
Select [Controller]-[Inputs / Outputs]-[Analog I/O].
Summary of Contents for RC700-D
Page 1: ...Control Unit RC700 D Original instructions Rev 2 EM221C5146F ROBOT CONTROLLER RC700 D Manual ...
Page 2: ...ROBOT CONTROLLER RC700 D Manual Rev 2 ...
Page 8: ...vi RC700 D Rev 2 ...
Page 16: ...Table of Contents xiv RC700 D Rev 2 ...
Page 18: ......
Page 80: ...Installation 5 Second Step 64 RC700 D Rev 2 ...
Page 82: ......
Page 87: ...Functions 1 Specifications RC700 D Rev 2 71 1 3 Outer Dimensions Unit mm ...
Page 190: ......
Page 202: ...Regular Inspection 3 Alarm 186 RC700 D Rev 2 ...
Page 203: ...187 Appendix ...
Page 204: ......