Functions 14. Option Slots
RC700-D Rev.2
157
14.6.4 Input Circuit (Analog I/O Board)
Input resolution
: 16 bit
Input range
: voltage input: 0 to 5.12V, 0 to 10.24V,
±
5.12V,
±
10.24V
current input: 0 to 24mA
Input impedance (Voltage/Current)
: Applox.100k
Ω
/Applox.422
Ω
Absolute rated voltage of input pins
:
±
11V
Insulation specification : insulation between channels, bus insulation
14.6.5 Output Circuit (Analog I/O Board)
Output resolution
: 16 bit
Output range
: voltage output: 0 to 5V, 0 to 10V,
±
5V,
±
10V
current output: 0 to 20mA, 4 to 20mA
Output impedance (Voltage/Current)
: Applox.17
Ω
/Applox.50M
Ω
Absolute rated voltage of output pins
:
±
11V
Load resistance/capacity (@voltage output)
: 1k
Ω
or more/5nF or less
Load resistance /inductance (@voltage output)
: 300k
Ω
or more/50mH or less
Insulation specification : insulation between channels, bus insulation
CAUTION
Analog input/output may not function properly if performing improper wiring or
configuration.
Operating under external noise may affect to the analog input/output. Make
sure the noise environment such as weather the cable is shielded.
Use the shield/twist cable.
Never apply a voltage or current which is out of input/output range to the analog
input/output pin. Applying a voltage more than
±
11V may result in malfunction
of the board.
Improper wiring or short circuit may cause malfunction of the parts on the board
and then improper function of the robot system.
Summary of Contents for RC700-D
Page 1: ...Control Unit RC700 D Original instructions Rev 2 EM221C5146F ROBOT CONTROLLER RC700 D Manual ...
Page 2: ...ROBOT CONTROLLER RC700 D Manual Rev 2 ...
Page 8: ...vi RC700 D Rev 2 ...
Page 16: ...Table of Contents xiv RC700 D Rev 2 ...
Page 18: ......
Page 80: ...Installation 5 Second Step 64 RC700 D Rev 2 ...
Page 82: ......
Page 87: ...Functions 1 Specifications RC700 D Rev 2 71 1 3 Outer Dimensions Unit mm ...
Page 190: ......
Page 202: ...Regular Inspection 3 Alarm 186 RC700 D Rev 2 ...
Page 203: ...187 Appendix ...
Page 204: ......