Installation 2. Installation
RC700-D Rev.2
33
AC Power Cable
WARNING
■
Make sure that operations are done by a qualified personal.
■
Be sure to connect the earth wire (green/yellow) of the AC
power cable to the earth terminal of the factory power supply.
The equipment must be grounded properly at all times to
avoid the risk of electric shock.
■
Always use a power plug or a disconnecting device for power
connecting cable. Never connect the Controller directly to
the factory power supply.
■
Select the plug or a disconnecting device which conform
safety standards for nations.
When connecting the plug of the AC power cable to the Controller, insert until it clicks as
shown in the figure below.
Following shows specification of power connection side.
Mount to the plug like following below.
Item
Specification
AC power wire
(2 cables)
Black, Black
Ground wire
Green / Yellow
Cable length
3 m
Terminal
M4 round solderless
terminal