2. Installation
RC700 / RC90 Option Fieldbus I/O Rev.14
195
Wiring
Use a standard Ethernet connector for wiring to the board.
CAUTION
You can use the general Ethernet hub or Ethernet switch for the EtherNet/IP.
However, be sure to use a product complying with the industrial standards or
noise resistant Ethernet cable (STP cable). If you use an office use product or
UTP cable, it may cause communication errors and may not offer the proper
performance.
Installing Module
WARNING
Make sure that the power is turned OFF before installing/removing any modules
or connecting/disconnecting any cables. Working with the power ON is
extremely hazardous and may result in electric shock and/or malfunction of
equipment.
Install the module to the dedicated slot on the T/VT series Manipulator.
Reference: Manipulator manual
Setup & Operation 17. Fieldbus I/O
Confirmation and Configuration of EPSON RC+ 7.0
When the EtherNet/IP slave module is installed to the T/VT series Manipulator, it is
recognized automatically. Confirm whether EPSON RC+ 7.0 has recognized the
EtherNet/IP slave module using the following procedure.
1. Select [Setup]-[System Configuration] and display the [System Configuration] dialog
box.
(2)
(3)
2. Select [Inputs / Outputs].
3. Confirm that the following items are displayed in “Fieldbus Slave”.
Installed
: Yes
Inputs
: 512-767 (default setting)
Outputs
: 512-767 (default setting)
Summary of Contents for RC700
Page 1: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 EM198C4088F ...
Page 2: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 ...
Page 8: ...vi RC700 RC90 Option Fieldbus I O Rev 14 ...
Page 12: ...Table of Contents x RC700 RC90 Option Fieldbus I O Rev 14 ...
Page 340: ...5 Maintenance Parts List 328 RC700 RC90 Option Fieldbus I O Rev 14 ...