2. Installation
RC700 / RC90 Option Fieldbus I/O Rev.14
219
Remote Register
Remote register (RWr, RWw) is numeric value
“m” indicated in the following tables are master station address configured with station
configure. This is calculated by the following expression.
m = (Station
−
1)
×
4
Result of the calculation is in decimal number. Substitute the result to “m” after
converting to hexadecimal number.
(Example)
When the CC-Link board is 1
Remote Register
RWrm to RWrm+B
→
RWr0 to RWrB
Remote Register
RWwm to RWwm+B
→
RWw0 to RWwB
When the CC-Link board is 4
Remote Register
RWrm to RWrm+B
→
RWrC to RWr17
Remote Register
RWwm to RWwm+B
→
RWwC to RWw17
Remote Register List (3 stations occupied, Default configuration *1)
Signal direction: Remote device station (CC-Link module)
→
Master station (PLC)
Bits indicated as “NA” are left for user. Use these free for SPEL+ program.
Address
Signal Name
Robot System
Word No.
Robot System
Bit No.
RWrm
NA
38
608 to 623
:
:
RWrm+9
NA
47
752 to 767
RWrm+A
System reserved
-
-
RWrm+B
System reserved
-
-
Signal direction: Master station (PLC)
→
Remote device station (CC-Link board)
Bits indicated as “NA” are left for user. Use these free for SPEL+ program.
Address
Signal Name
Robot System
Word No.
Robot System
Bit No.
RWwm
NA
38
608 to 623
:
:
RWwm+9
NA
47
752 to 767
RWwm+A System reserved
-
-
RWwm+B System reserved
-
-
Summary of Contents for RC700
Page 1: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 EM198C4088F ...
Page 2: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 ...
Page 8: ...vi RC700 RC90 Option Fieldbus I O Rev 14 ...
Page 12: ...Table of Contents x RC700 RC90 Option Fieldbus I O Rev 14 ...
Page 340: ...5 Maintenance Parts List 328 RC700 RC90 Option Fieldbus I O Rev 14 ...