2. Installation
240
RC700 / RC90 Option Fieldbus I/O Rev.14
2.6.2 Installing EtherCAT Slave Module
WARNING
■
Make sure that the power is turned OFF before installing/removing any modules
or connecting/disconnecting any cables. Working with the power ON is
extremely hazardous and may result in electrical shock and/or malfunction of
equipment.
CAUTION
■
Pay attention to the followings in order to prevent the the connecter from coming
off.
1. Use the connectors attached to the module.
2. Insert the connectors all the way seated.
3. Fix the cables at proper positions in order not to put a load on the
connectors.
Appearance
RUN LED
ERR LED
IN port
OUT port
Link/Activity LED
Specifications
Item
Specification
Name
EtherCAT module
Protocol
EtherCAT
Transmission Type
100BASE-TX
Baud Rate
100 M bps, full duplex
Maximum Segment Length
100m
Maximum Number of Nodes
65535
Cable
100BASE-TX(Cat5) with RJ45 connector
Interface
Two RJ45 ports
IN: EtherCAT input / OUT: EtherCAT Output
Input Data Size
Max. 2048 bits (256 bytes)
Output Data Size
Max. 2048 bits (256 bytes)
Device Profile
CANopen over EtherCAT (CoE)
PDO (Process Data Object)
SDO (Service Data Object)
Summary of Contents for RC700