2. Installation
RC700 / RC90 Option Fieldbus I/O Rev.14
243
(4)
Select [Fieldbus Slave]-[General]
(4)
(5)
(5)
Confirm that the following items are displayed.
Fieldbus Type
: EtherCAT
Input Bytes
: 32 (default setting)
Output Bytes
: 32 (default setting)
(6)
Click <Close>.
Editing of Input / Output Size
You can change the input/output size of the EtherCAT slave module if necessary.
(1)
Select [Setup]-[System Configuration] and display the [System Configuration] dialog
box.
(2)
Select [Inputs / Outputs]-[Fieldbus Slave]-[General].
(3)
Change the settings of [Input Bytes] and [Output Bytes].
In this example, both of them are changed to “20” Bytes.