5. General Maintenance
98
Safety and Installation (RC90-B / EPSON RC+ 7.0) Rev.4
5.1.2 Controller
Part
Fan filter
Fan
Battery
Content
Cleaning
Replacement
Replacement
Replacement
Code
-
R13B60511
R13B060510
R13B060003
Quantity
-
1
1
1
Maintenance
interval
More than once a
month is
recommended
When the filter
gets deteriorated
When the error
515 occurs, or
when the
abnormal noise
occurs
Every 5 years,
or when the
error 511 occurs
Possible
malfunction if
maintenance is
not performed
The temperature
inside the Controller
may get too high
and the robot
system may not
operate properly.
The error may occur
due to reduction of
the fun rotation.
The robot
system may not
operate properly
due to dust or
the like.
The error 9015
occurs and the
robot system may
stop.
The error 9011
occurs and the
robot system
may stop.
Duration
(reference)
5 minutes
5 minutes
20 minutes
15 minutes
Reference:
Controller Manual
Maintenance
7.1
Fan Filter
7.1
Fan Filter
7.2
Fan
7.3
Battery
Expected product
life
-
-
30,000 hours
-