Maintenance 4. Backup and Restore
RC90 (EPSON RC+ 7.0) Rev.8
89
(4)
Click the <OK> button to display the dialog to select the restore data.
Robot name, serial #, calibration
This checkbox allows you to restore the robot name, robot serial number, Hofs data,
and CalPls data. Make sure that the correct Hofs data is restored. If the wrong Hofs
data is restored, the robot may move to wrong positions.
The default setting is unchecked.
Project
This checkbox allows you to restore the files related to projects.
The default is unchecked.
When a project is restored, the values of Global Preserve variables are loaded.
For details about Global Preserve variable backup, refer to
EPSON RC+ 7.0 User’s
Guide 5.10.10 Display Variables Command (Run Menu)
.
Vision hardware configuration
This checkbox allows you to restore the vision hardware configuration.
For details, refer to
EPSON RC+ 7.0 option Vision Guide 7.0
.
This is not checked by the default setting.
Security configuration checkbox
This checkbox allows you to restore the security configuration.
For details, refer to
EPSON RC+ 7.0 User’s Guide 15. Security
.
This is not checked by the default setting.
(5)
Click the <OK> button to restore the system information.
Restore the system configuration saved using Backup Controller only for the same
system.
When different system information is restored, the following warning message appears.
Click the <No> button (do not restore data) except for special situations such as
controller replacement.
NOTE
Summary of Contents for RC90
Page 1: ...Rev 8 EM158C3031F ROBOT CONTROLLER RC90 EPSON RC 7 0 ...
Page 2: ...ii ROBOT CONTROLLER RC90 EPSON RC 7 0 Rev 8 ...
Page 10: ...viii RC90 EPSON RC 7 0 Rev 8 ...
Page 17: ...Safety This section contains information for safety of the Robot System ...
Page 18: ......
Page 24: ......
Page 28: ...Setup Operation 1 Specifications 12 RC90 EPSON RC 7 0 Rev 8 1 3 Outer Dimensions Unit mm ...
Page 95: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 96: ......