Maintenance 9. Troubleshooting
RC90 (EPSON RC+ 7.0) Rev.8
126
No.
Message
Remedy
Note 1
Note 2
1806
Timeout during connection via
Ethernet.
-
1807
Timeout during connection via USB.
-
1808
USB driver is not installed.
Failed to install EPSON RC+ 7.0.
Install EPSON RC+ 7.0 again.
1809
Initialization failure.
Failed to initialize PC daemon.
Reboot the System.
1810
PC daemon error.
Uncommon error.
1.
Reboot the EPSON RC+7.0.
2.
Reboot the PC.
1812
Connection failure.
The connected controller is not
supported in EPSON RC+ 7.0.
Please use EPSON RC+ 5.0.
Connected controller is RC180 or RC90
compatible with EPSON RC+ 5.0.
Check the connection between the PC
and controller.
1852
System error.
Uncommon error.
1.
Reboot the EPSON RC+7.0.
2.
Reboot the PC.
3.
Reinstall the EPSON RC+ 7.0.
1861
Initialization failure.
Failed to initialize SimulatorMNG.
1.
Reboot the EPSON RC+ 7.0.
2.
Reboot the PC.
3.
Reinstall the EPSON RC+ 7.0.
1862
Initialization failure.
Failed to initialize WBProxy.
1.
Reboot the EPSON RC+ 7.0.
2.
Reboot the PC.
3.
Reinstall the EPSON RC+ 7.0.
1863
The parameter is invalid.
-
1864
Initialization failure.
Virtual controller does not exist.
Installation of the EPSON RC+ 7.0
failed. Reinstall the software.
1865
Initialization failure.
Failed to start virtual controller.
1.
Retry after a while.
2.
Reboot the PC.
1867
Cannot execute because it is not dry
run mode.
Dry run mode is invalid.
Enable the dry run.
1868
Initialization failure.
Directory cannot be found.
Installation of the EPSON RC+ 7.0
failed. Reinstall the software.
1872
Connection failure.
Files for simulator that used real
controller cannot be found.
-
1873
Connection failure.
Files for simulator that used virtual
controller cannot be found.
-
1874
Virtual Controller cannot be added.
Installation of the EPSON RC+ 7.0
failed. Reinstall the software.
1875
Simulator Object failure.
Cannot load data for the simulator
object.
-
1876
Simulator Object failure.
Cannot read data for the simulator
object.
-
1877
Simulator Object failure.
Cannot remove data from the
simulator object.
-
1878
Simulator Object failure.
Cannot update data for the simulator
object.
-
1879
Other virtual controllers are starting.
Other virtual controllers may be used in
the EPSON RC+ 5.0.
Or, the virtual controller may be already
used in another EPSON RC+7.0.
Summary of Contents for RC90
Page 1: ...Rev 8 EM158C3031F ROBOT CONTROLLER RC90 EPSON RC 7 0 ...
Page 2: ...ii ROBOT CONTROLLER RC90 EPSON RC 7 0 Rev 8 ...
Page 10: ...viii RC90 EPSON RC 7 0 Rev 8 ...
Page 17: ...Safety This section contains information for safety of the Robot System ...
Page 18: ......
Page 24: ......
Page 28: ...Setup Operation 1 Specifications 12 RC90 EPSON RC 7 0 Rev 8 1 3 Outer Dimensions Unit mm ...
Page 95: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 96: ......