Maintenance 9. Troubleshooting
RC90 (EPSON RC+ 7.0) Rev.8
141
No.
Message
Remedy
Note 1
Note 2
2384
Case or Send was used without Select.
Review the program.
Review the program.
2385
Cannot execute EResume while
executing GoSub.
Review the program.
2386
EResume was used without OnErr.
Review the program.
Review the program.
2400
Curve failure.
Failed to open the Curve file.
Reboot the controller.
Create a Curve file again.
2401
Curve failure.
Failed to allocate the header data of the
curve file.
Reboot the controller.
Create a Curve file again.
2402
Curve failure.
Failed to write the curve file.
Reboot the controller.
Create a Curve file again.
2403
Curve failure.
Failed to open the curve file.
Reboot the controller.
Create a Curve file again.
2404
Curve failure.
Failed to update the curve file.
Reboot the controller.
Create a Curve file again.
2405
Curve failure.
Failed to read the curve file.
Reboot the controller.
Create a Curve file again.
2406
Curve failure.
Curve file is corrupt.
Reboot the controller.
Create a Curve file again.
2407
Curve failure.
Specified a file other than a curve file.
Reboot the controller.
Create a Curve file again.
2408
Curve failure.
Version of the curve file is invalid.
Reboot the controller.
Create a Curve file again.
2409
Curve failure.
Robot number in the curve file is
invalid.
Reboot the controller.
Create a Curve file again.
2410
Curve failure.
Cannot allocate enough memory for
the CVMove statement.
Reboot the controller.
2411
Specified point data in the Curve
statement is beyond the maximum
count.
The maximum number of points
specified in the Curve statement is 200.
Review the program.
2412
Specified number of output commands
in the Curve statement is beyond the
maximum count.
The maximum number of output
commands specified in the Curve
statement is 16. Review the program.
2413
Curve failure. Specified internal code
is beyond the allowable size in Curve
statement.
Reboot the controller.
2414
Specified continue point data P(:) is
beyond the maximum count.
The maximum number of points
specified continuously is 200. Review
the program.
Start point
End point
2415
Curve failure.
Cannot create the curve file.
Reboot the controller.
Create a Curve file again.
2416
Curve file does not exist.
Check whether the specified Curve file
name is correct.
2417
Curve failure.
Output command is specified before
the point data.
Check whether no output command is
specified before the point data.
2430
Error message failure.
Error message file does not exist.
Reboot the controller.
2431
Error message failure.
Failed to open the error message file.
Reboot the controller.
Summary of Contents for RC90
Page 1: ...Rev 8 EM158C3031F ROBOT CONTROLLER RC90 EPSON RC 7 0 ...
Page 2: ...ii ROBOT CONTROLLER RC90 EPSON RC 7 0 Rev 8 ...
Page 10: ...viii RC90 EPSON RC 7 0 Rev 8 ...
Page 17: ...Safety This section contains information for safety of the Robot System ...
Page 18: ......
Page 24: ......
Page 28: ...Setup Operation 1 Specifications 12 RC90 EPSON RC 7 0 Rev 8 1 3 Outer Dimensions Unit mm ...
Page 95: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 96: ......