Maintenance 9. Troubleshooting
RC90 (EPSON RC+ 7.0) Rev.8
142
No.
Message
Remedy
Note 1
Note 2
2432
Error message failure.
Failed to obtain the header data of the
error message file.
Reboot the controller.
2433
Error message failure.
Error message file is corrupted.
Reboot the controller.
2434
Error message failure.
Specified a file other than the error
message file.
Reboot the controller.
2435
Error message failure.
Version of the error message file is
invalid.
Reboot the controller.
2440
File Error.
File number is already used.
Check the file number.
2441
File Error.
Failed to open the file.
Make sure the file exists and you
specified the file correctly.
2442
File Error.
The file is not open.
Open the file in advance.
2443
File Error. The file number is being
used by another task.
Check the program.
2444
File Error. Failed to close the file.
Check the file.
2445
File Error. File seek failed.
Review the program.
Check the pointer setting.
2446
File Error.
All file numbers are being used.
Close unnecessary files.
2447
File Error.
No read permission.
Use ROpen or UOpen that has read
access to the file.
2448
File Error.
No write permission.
Use WOpen or UOpen that has write
access to the file.
2449
File Error.
No binary permission.
Use BOpen that has binary access to the
file.
2450
File Error.
Failed to access the file.
Check the file.
2451
File Error. Failed to write the file.
Check the file.
2452
File Error. Failed to read the file.
Check the file.
2453
File Error.
Cannot execute the command for
current disk.
The specified command is not available
in the current disk (ChDisk).
2454
File Error. Invalid disk.
Review the program.
2455
File Error. Invalid drive.
Review the program.
2456
File Error. Invalid folder.
Review the program.
2460
Database Error.
The database number is already being
used.
Review the program.
Specify the number of other database.
Close the database.
2461
Database Error.
The database is not open.
Review the program.
Open the database.
2462
Database Error.
The database number is being used by
another task.
Review the program.
2470
Windows Communication Error.
Invalid status.
Reboot the Controller.
Rebuild the project.
Summary of Contents for RC90
Page 1: ...Rev 8 EM158C3031F ROBOT CONTROLLER RC90 EPSON RC 7 0 ...
Page 2: ...ii ROBOT CONTROLLER RC90 EPSON RC 7 0 Rev 8 ...
Page 10: ...viii RC90 EPSON RC 7 0 Rev 8 ...