Maintenance 9. Troubleshooting
RC90 (EPSON RC+ 7.0) Rev.8
143
No.
Message
Remedy
Note 1
Note 2
2471
Windows Communication Error.
Invalid answer.
Reboot the Controller.
Rebuild the project.
2472
Windows Communication Error.
Already initialized.
Reboot the Controller.
2473
Windows Communication Error.
Busy.
Reboot the Controller.
Rebuild the project.
2474
Windows Communication Error. No
request.
Reboot the Controller.
Rebuild the project.
2475
Windows Communication Error.
Data buffer overflow.
Reduce the data volume.
Review the program.
2476
Windows Communication Error.
Failed to wait for event.
Reboot the Controller.
2477
Windows Communication Error.
Invalid folder.
Make sure the specified folder is correct.
2478
Windows Communication Error.
Invalid error code.
Rebuild the project.
2500
Specified event condition for Wait is
beyond the maximum count.
The maximum number of event
conditions is 8. Review the program.
2501
Specified bit number in the Ctr
function was not initialized with a
CTReset statement.
Review the program.
The specified
bit number
2502
Task number is beyond the maximum
count to execute.
The available number of the tasks that
can be executed simultaneously is 16.
Review the program.
2503
Cannot execute Xqt when the specified
task number is already executing.
Review the program.
The specified
task number
2504
Task failure. Specified manipulator
is already executing a parallel process.
Rebuild the project.
2505
Not enough data for Input statement
variable assignment.
Check the content of communication
data. Review the program.
2506
Specified variable for the Input
statement is beyond the maximum
count.
For OP, only one variable can be
specified. For other devices, up to 32
variables can be specified.
2507
All counters are in use and cannot
initialize a new counter with CTReset.
The available number of the counters
that can be set simultaneously is 16.
Review the program.
2508
OnErr failure. Failed to process the
OnErr statement.
Rebuild the project.
2509
OnErr failure. Failed to process the
OnErr statement.
Rebuild the project.
2510
Specified I/O label is not defined.
The specified I/O label is not registered.
Check the I/O label file.
2511
SyncUnlock statement is used without
executing a previous SyncLock
statement. Review the program.
Review the program.
Signal number
2512
SyncLock statement was already
executed.
The SyncLock statement cannot be
executed for the second time in a row.
Review the program.
Signal number
2513
Specified point label is not defined.
The specified point label is not
registered. Check the point file.
2514
Failed to obtain the motor on time of
the robot.
Reboot the controller.
Summary of Contents for RC90
Page 1: ...Rev 8 EM158C3031F ROBOT CONTROLLER RC90 EPSON RC 7 0 ...
Page 2: ...ii ROBOT CONTROLLER RC90 EPSON RC 7 0 Rev 8 ...
Page 10: ...viii RC90 EPSON RC 7 0 Rev 8 ...
Page 17: ...Safety This section contains information for safety of the Robot System ...
Page 18: ......
Page 24: ......
Page 28: ...Setup Operation 1 Specifications 12 RC90 EPSON RC 7 0 Rev 8 1 3 Outer Dimensions Unit mm ...
Page 95: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 96: ......