Maintenance 9. Troubleshooting
RC90 (EPSON RC+ 7.0) Rev.8
154
No.
Message
Remedy
Note 1
Note 2
3227
Function name was not specified.
Function name is not specified in the
statement that requires function name
designation, such as Call and Xqt.
Specify a valid function name.
3228
Variable type was not specified.
Variable type is not specified for the
parameter definition of Function
statement and Preserve parameter
specification of Global statement.
Specify a correct variable type.
3229
Invalid Trap statement parameter.
Use Goto, Call, or Xqt.
Specify either GoTo, Call, or Xqt as a
parameter of Trap statement.
3230
Expected For/Do/Function.
Specify either For, Do, or Function as a
parameter of Exit statement.
3231
Above/Below was not specified.
Setting value for the elbow orientation is
not specified in Elbow statement.
Specify either Above or Below.
3232
Righty/Lefty was not specified.
Setting value for the hand orientation is
not specified in Hand statement.
Specify either Righty or Lefty.
3233
NoFlip/Flip was specified.
Setting value for the wrist orientation is
not specified in Wrist statement.
Specify either NoFilip or Flip.
3234
Port number was not specified.
Port number that indicates the file or
communication port is not specified in
Read, ReadBin, Write, and WriteBin
statements.
Refer to
SPEL+ Language Reference
“
Read Statement
” and specify a proper
file number or port number.
3235
String type variable was not specified.
String type variable is not specified in
the command that requires specification
of string type variable as a parameter.
Specify a valid string type variable.
3236
RS-232C port number was not
specified.
RS-232C port number is not specified in
OpenCom, CloseCom, and SetCom
statements. Refer to
SPEL+ Language
Reference
“
OpenCom Statement
” and
specify a proper port number.
3237
Network communication port number
was not specified.
Network communication port number is
not specified in OpenNet, CloseNet,
SetNet, and WaitNet statement.
Specify an integer from 201 to 216.
3238
Communication speed was not
specified.
Communication speed (baud rate) is not
specified in SetCom statement. Refer
to
SPEL+ Language Reference “SetCom
Statement”
and specify a proper baud
rate.
3239
Data bit number was not specified.
Data bit length is not specified in
SetCom statement. Refer to
SPEL+
Language Reference
“SetCom
Statement”
and specify a proper data bit
length.
3240
Stop bit number was not specified.
Stop bit length is not specified in
SetCom statement. Refer to
SPEL+
Language Reference
“SetCom
Statement”
and specify a proper stop bit
length.
Summary of Contents for RC90
Page 1: ...Rev 8 EM158C3031F ROBOT CONTROLLER RC90 EPSON RC 7 0 ...
Page 2: ...ii ROBOT CONTROLLER RC90 EPSON RC 7 0 Rev 8 ...
Page 10: ...viii RC90 EPSON RC 7 0 Rev 8 ...
Page 17: ...Safety This section contains information for safety of the Robot System ...
Page 18: ......
Page 24: ......
Page 28: ...Setup Operation 1 Specifications 12 RC90 EPSON RC 7 0 Rev 8 1 3 Outer Dimensions Unit mm ...
Page 95: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 96: ......