Maintenance 9. Troubleshooting
RC90 (EPSON RC+ 7.0) Rev.8
158
No.
Message
Remedy
Note 1
Note 2
3280
StartPosition was not specified.
StartPosition property setting value is not
specified in GSet statement. Refer to
GUI Builder 7.0
manual “
StartPosition
Property
” and specify a proper setting
value.
3281
TextAlign was not specified.
TextAlign property setting value is not
specified in GSet statement.
This error occurs when the control type
cannot be identified because the control
is specified by a string variable. Refer
to
GUI Builder 7.0
manual “
TextAlign
Property
” and specify a proper setting
value.
3282
TextAlign was not specified.
TextAlign property setting value is not
specified in GSet statement.
This error occurs when the control is a
text box. Refer to
GUI Builder 7.0
manual “
TextAlign Property
” and
specify a proper setting value.
3283
TextAlign was not specified.
TextAlign property setting value is not
specified in GSet statement.
This error occurs when the control is
other than a text box. Refer to
GUI
Builder 7.0
manual “
TextAlign Property
”
and specify a proper setting value.
3284
WindowState was not specified.
WindowState property setting value is
not specified in GSet statement.
Refer to
GUI Builder 7.0
manual
“
WindowState Property
” and specify a
proper setting value.
3285
J1FLAG was not specified.
Specify 0 or 1, or an expression for
J1Flag value.
3286
J2FLAG was not specified.
Specify 0 or 1, or an expression for
J2Flag value.
3287
robotID was not specified.
Specify a robot number.
3288
robotID/All was not specified.
Robot number or All is not specified in
InsideBox and InsidePlane function.
Specify a robot number which performs
intrusion detection, or All.
3289
areaID was not specified.
Area number is not specified in
InsideBox and InsidePlane function.
Specify an approach check area number
which returns status by an integer from 1
to 15.
3290
File number was not specified.
File number is not specified in the
command related to file management.
Specify a file number by an integer from
30 to 63 or an expression.
3292
Database type was not specified.
Database type is not specified in
OpenDB statement. Refer to
SPEL+
Language Reference
“
OpenDB
Statement
” and specify a proper database
type.
Summary of Contents for RC90
Page 1: ...Rev 8 EM158C3031F ROBOT CONTROLLER RC90 EPSON RC 7 0 ...
Page 2: ...ii ROBOT CONTROLLER RC90 EPSON RC 7 0 Rev 8 ...
Page 10: ...viii RC90 EPSON RC 7 0 Rev 8 ...
Page 17: ...Safety This section contains information for safety of the Robot System ...
Page 18: ......
Page 24: ......
Page 28: ...Setup Operation 1 Specifications 12 RC90 EPSON RC 7 0 Rev 8 1 3 Outer Dimensions Unit mm ...
Page 95: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 96: ......