Maintenance 9. Troubleshooting
RC90 (EPSON RC+ 7.0) Rev.8
162
No.
Message
Remedy
Note 1
Note 2
3411
Edge type is not specified.
EdgeType property setting value is not
specified in VSet statement. Refer to
Vision Guide 7.0 Properties & Results
Reference
“
EdgeType Property
” and
specify a proper setting value.
3412
ECC type is not specified.
ErrorCorrection property setting value is
not specified in VSet statement. This
error is for the old RC+6.x. Setting of
the old version is possible by compiler
version setting. Refer to
Vision Guide
6.0 Properties & Results Reference
“
ErrorCorrection Property
” and specify
a proper setting value.
3413
ImageColor type is not specified.
ImageColor property setting value is not
specified in VSet statement. Refer to
Vision Guide 7.0
Properties & Results
Reference “ImageColor Property
” and
specify a proper setting value.
3414
Point type is not specified.
PointType property setting value is not
specified in VSet statement. Refer to
Vision Guide 7.0 Properties & Results
Reference
“
PointType Property
” and
specify a proper setting value.
3415
Reference type is not specified.
ReferenceType property setting value is
not specified in VSet statement. Refer
to
Vision Guide 7.0 Properties & Results
Reference
“
ReferenceType Property
” and
specify a proper setting value.
3416
Edge type is not specified.
Logic (edge type) of the trigger input is
not specified in SetLatch statement.
Specify either 0 (negative logic) or
1(positive logic).
3417
Port number is not specified.
R-I/O input port number where the
trigger input is connected is not specified
in SetLatch statement. Refer to
SPEL+
Language Reference
“
SetLatch
Statement
” and specify a proper port
number.
3418
Axis is not specified.
Axis parameter is not specified in
Force_GetForce function or
Force_SetTrigger statement.
Refer to
SPEL+ Language Reference
“
Force_GetForce Function
” and specify
a proper setting value.
3419
CompareType is not specified.
ComapreType parameter to set judgment
condition is not specified in
Force_SetTrigger statement.
Refer to
SPEL+ Language Reference
“
Force_SetTrigger Statement
” and
specify a proper parameter.
3420
Integer or Short type array variable is
only available.
-
Summary of Contents for RC90
Page 1: ...Rev 8 EM158C3031F ROBOT CONTROLLER RC90 EPSON RC 7 0 ...
Page 2: ...ii ROBOT CONTROLLER RC90 EPSON RC 7 0 Rev 8 ...
Page 10: ...viii RC90 EPSON RC 7 0 Rev 8 ...
Page 17: ...Safety This section contains information for safety of the Robot System ...
Page 18: ......
Page 24: ......
Page 28: ...Setup Operation 1 Specifications 12 RC90 EPSON RC 7 0 Rev 8 1 3 Outer Dimensions Unit mm ...
Page 95: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 96: ......