Maintenance 9. Troubleshooting
RC90 (EPSON RC+ 7.0) Rev.8
165
No.
Message
Remedy
Note 1
Note 2
3607
Invalid object index was specified.
Invalid index is specified in Objects
property of VSet and VGet statements.
The index must be larger than 1 and
smaller than the number of objects in the
specified sequence. Specify a proper
index.
3608
Invalid control index was specified.
Invalid index is specified in Controls
property of GSet and GGet statements.
The index must be larger than 1 and
smaller than the number of controls in
the specified form. Specify a proper
index.
3800
Compile process aborted.
-
3801
Link process aborted.
-
3802
Compile process aborted. Compile
errors reached the maximum count.
Correct the error in the program and
rebuild the project.
3803
Link process aborted. Link errors
reached the maximum count.
Correct the error in the program and
rebuild the project.
3804
Specified command cannot be
executed from the Command window.
Declaration of variables and functions,
program control statement, preprocessor
commands, and some commands cannot
be executed from the command window.
For details, refer to
SPEL+ Language
Reference
“
Appendix A
:
SPEL+
Command Use Condition List
”.
3805
Specified command can only be
executed from the Command window.
Brake, SysConfig, Where, Cnv_QueList,
and WorlQue_List statements can only
be executed from the command window.
Delete these statements from the
program.
3806
Specified function cannot be executed
from the Command window.
LogIn function cannot be executed from
the command window even when used
with Print statement. Use the function
in the program.
3808
Specified syntax cannot be used in the
current version.
LJM and PerformMode parameters of
motion commands may not be specified
depending on the compiler version.
LJM parameter: 6.0.x.x or later
PerformMode parameter: 7.0.4.x or later
Check the compiler version from the
project property.
3809
Module variables cannot be used in the
command window.
Module variable cannot be accessed from
the command window. Check the input
command.
3812
Specified function cannot be used with
a Remote User Output.
Functions for condition expression of the
user defined remote output are limited.
Refer to
EPSON RC+7.0 User’s Guide
“
11.8 User-defined Remote Output I/O
”
and specify a valid function.
3813
User defined label, function and
variable cannot be used with a Remote
User Output.
User defined label, function and variable
cannot be used with condition expression
of the user-defined remote output.
Correct the condition expression.
Summary of Contents for RC90
Page 1: ...Rev 8 EM158C3031F ROBOT CONTROLLER RC90 EPSON RC 7 0 ...
Page 2: ...ii ROBOT CONTROLLER RC90 EPSON RC 7 0 Rev 8 ...
Page 10: ...viii RC90 EPSON RC 7 0 Rev 8 ...
Page 17: ...Safety This section contains information for safety of the Robot System ...
Page 18: ......
Page 24: ......
Page 28: ...Setup Operation 1 Specifications 12 RC90 EPSON RC 7 0 Rev 8 1 3 Outer Dimensions Unit mm ...
Page 95: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 96: ......