Maintenance 9. Troubleshooting
RC90 (EPSON RC+ 7.0) Rev.8
194
No.
Message
Remedy
Note 1
Note 2
7502
Smart camera.
Project has not been set.
Rebuild the project.
7503
Smart camera.
Vision property or result not
supported.
Update the camera firmware.
7504
Smart camera.
Cannot open project file.
Rebuild the project.
7505
Undefined vision sequence.
Check the sequence name.
Rebuild the project.
7506
Undefined vision object.
Check the object name.
Rebuild the project.
7507
Smart camera.
Critical error.
Initialize the camera.
Rebuild the project.
7508
Smart camera.
Invalid command.
Update the camera firmware.
7509
Invalid vision property value.
Check the property value.
Update the camera firmware.
7510
Invalid vision property.
Check the property name.
Update the camera firmware.
7511
Vision model not trained.
Teach the model.
7512
Undefined vision calibration.
Check the calibration name.
Rebuild the project.
7513
Vision model object not Self.
Check the property value.
7514
Invalid vision result.
Check the result name.
Update the camera firmware.
7515
Vision object not found.
Check the Found result before obtaining
the result.
7516
No vision calibration.
Check the calibration name.
7517
Incomplete vision calibration.
Perform calibration.
7518
Smart camera.
Cannot connect with camera.
Check the camera connection.
7819
Smart camera.
Communication error.
Check the camera connection.
7520
Window out of bounds.
Set the window within the bounds.
7521
OCR font is invalid.
Register the OCR font.
7522
The specified vision calibration
already exists.
Change the calibration name.
Delete the existing calibration in
advance.
7523
The specified vision sequence already
exists.
Change the sequence name.
Delete the existing sequence in advance.
7524
The specified vision object already
exists.
Change the object name.
Delete the existing sequence in advance.
7525
Cannot load vision project.
The project folder may be corrupt.
Restore backup data.
7526
Cannot save vision project.
The project folder may be write-protect.
Check the access permission for the
project folder.
7527
Vision processor. Critical error.
Initialize the camera.
Rebuild the project.
7528
Image file not found.
Check the image file.
7529
Camera does not exist.
Check the camera connection.
7530
Acquisition failed.
Check the camera connection.
7531
Vision object is not taught.
Teach the model.
7532
Image file cannot be read.
Check the image file.
Summary of Contents for RC90
Page 1: ...Rev 8 EM158C3031F ROBOT CONTROLLER RC90 EPSON RC 7 0 ...
Page 2: ...ii ROBOT CONTROLLER RC90 EPSON RC 7 0 Rev 8 ...
Page 10: ...viii RC90 EPSON RC 7 0 Rev 8 ...