Setup & Operation 2. Part Names and Functions
RC90 (EPSON RC+ 7.0) Rev.8
15
(19) Option slot
Option boards such as expansion I/O board, Fieldbus I/O board, RS-232C board, PG
board can be installed. Two slots are available.
For details, refer to
Setup & Operation 13.Option Slots
.
(20) Cable Clamp
This can be used to secure the M/C Power Cable and the AC Power cable.
(21) Battery
(Mounted inside the controller)
This is a lithium battery for data backup.
2.3 LED
Five LEDs are located on the front panel of the Controller.
LEDs (ERROR, E-STOP, TEACH, AUTO, PROGRAM) turn ON according to the
controller status (error, Emergency Stop, TEACH mode, Auto mode, Program mode).
From turning ON the Controller to completing startup
Three LEDs (TEACH, AUTO, PROGRAM) blink.
After Controller Startup
Controller status
LED display
Execute Controller status
storage function to the
USB memory
TEACH AUTO, PROGRAM blink.
Complete Controller status
storage to USB memory
TEACH, AUTO, PROGRAM turn ON
(for 2 seconds).
ERROR turns OFF even if an error occurs.
Failure of Controller status
storage to USB memory
ERROR, TEACH, AUTO, PROGRAM turn ON
(for 2 seconds).
Error
ERROR turns ON
Warning
ERROR blinks.
Emergency Stop
E-STOP turns ON.
TEACH mode
TEACH blinks.
Auto mode (AUTO mode)
AUTO blinks.
Program mode (AUTO mode)
PROGRAM blinks.
Recovery mode
ERROR, TEACH, PROGRAM turn ON.
AC power supply drop
TEACH, AUTO turn ON.
Test mode
TEACH blinks.
Summary of Contents for RC90
Page 1: ...Rev 8 EM158C3031F ROBOT CONTROLLER RC90 EPSON RC 7 0 ...
Page 2: ...ii ROBOT CONTROLLER RC90 EPSON RC 7 0 Rev 8 ...
Page 10: ...viii RC90 EPSON RC 7 0 Rev 8 ...
Page 17: ...Safety This section contains information for safety of the Robot System ...
Page 18: ......
Page 24: ......
Page 28: ...Setup Operation 1 Specifications 12 RC90 EPSON RC 7 0 Rev 8 1 3 Outer Dimensions Unit mm ...
Page 95: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 96: ......